Wolf BM-Solar Installation And Operating Instructions Manual page 13

Programming module
Table of Contents

Advertisement

A : 1 9
SM1: Not installed
SM2: Maximum DHW
temperature
Solar cylinder 3
A : 20
SM1: Not installed
SM2: Hours run
Solar circuit pump 3
A : 21
SM1: Not installed
SM2: Solar heating status
Cylinder 3
3061916_0611
Display level
SM1: Not installed
SM2: The maximum DHW temperature of cylinder 3 over the
course of 24 hours is displayed.
This value is reset every 24 hours.
SM1: Not installed
SM2: The overall hours run by solar circuit pump 3 are displayed.
This value corresponds to the display value x 10.
This value can be reset to 0 by pressing and holding down
the rotary selector for at least 10 seconds.
SM1: Not installed
SM2: This indicates whether solar heating of cylinder 3 has been
completed successfully within the last 24 hours.
This applies if, within 24 hours prior to 14:00 h, the set
DHW temperature selected at the heating appliance was exceeded
by solar heating.
In this case, the set DHW temperature at the heating appliance
will be set to the minimum cylinder temperature (cylinder reheating
blocked).
This function is only available if the solar module is operated as
part of a Wolf control system (for a function description, see the
SM solar module manual).