Electrical Connections; Condensate Drain - Beko DRYPOINT RA 3 Installation And Operation Instructions Manual

Compressed-air refrigeration dryer
Table of Contents

Advertisement

Installation
9.6

Electrical connections

Danger!
Supply voltage!
The connection to the electric mains should only be carried out by qualified skilled personnel and must
correspond to the legal provisions in force in your region.
Prior to connecting the device, please check the type plate to avoid exceeding the indicated values. The voltage toler-
ance is +/- 5%.
DRYPOINT RA 3-60 dryers are supplied with a VDE 16A standard power cord and safety plug (two-pole and earth
connection). DRYPOINT RA 80-160 devices have a junction box on the back plate.
Make sure that suitable fuses or circuit breakers in accordance with the indications on the type plate are available.
The wall socket must be equipped with a fault current circuit breaker (In=0,03A) which must be adjusted according to
the power consumption of the dryer (see nominal values on the type plate of the dryer). The cross-section of the power
supply cable must correspond to the power consumption of the dryer. In this respect, the ambient temperature, the
cable laying conditions, the length of the cables and the requirements of the local electricity supplier need to be con-
sidered.
Danger!
Supply voltage and missing earth connection!
Important: ensure that the plant is connected to earth.
Do not use plug adapters at the power plug.
Possible replacement of the power plug must only be carried out by a qualified electrician.
9.7

Condensate drain

Danger!
Compressed air and condensate under pressure!
The condensate is discharged at system pressure.
The drain pipe needs to be secured.
Never direct the condensate drain pipe at persons.
The dryer is delivered with an already integrated electronically level-controlled BEKOMAT condensate drain. Connect
the condensate drain with a collection system or container by properly screwing it on.
Do not connect the drain with pressure plants.
Do not discharge the condensate into the environment.
The condensate accumulating in the dryer contains oil particles which were released into the air by the
compressor.
Dispose of the condensate in accordance with the local provisions.
It is advisable to install a water-oil separator, to which the total amount of condensate from the compres-
sors, dryers, tanks, filters etc. is supplied.
We recommend ÖWAMAT oil-water separators for dispersed compressor condensate and BEKOSPLIT
emulsion-splitting plants for emulsified condensate.