Connection To The Compressed-Air System; Connection To The Cooling-Water Network (Water-Cooled) - Beko DRYPOINT RA 3 Installation And Operation Instructions Manual

Compressed-air refrigeration dryer
Table of Contents

Advertisement

9.4

Connection to the compressed-air system

Danger!
Compressed air!
All works must only be carried out by qualified skilled personnel.
Never work on compressed-air systems which are under pressure.
The operator or the user must ensure that the dryer is never operated with a pressure exceeding the
maximum pressure value indicated on the type plate.
Exceeding the maximum operating pressure can be dangerous for the operator but also for the device.
The air temperature and the air flow at the inlet of the dryer must lie within the limit values indicated on the type plate.
The connecting lines must be free from dust, iron rust, shards and other contaminations and correspond to the flow
rate of the dryer. Should air with a very high temperature be treated, the installation of an aftercooler may be neces-
sary. For the implementation of maintenance works, the installation of a bypass system is recommended, as is shown
in the following illustration.
Ø
The dryer was designed in such a manner that vibrations that may occur during operation are limited. Therefore, it is
advisable to employ connecting lines (flexible hoses, vibration-inhibiting fittings etc.) which protect the dryer against
possible vibrations in the pipework.
Note:
During the piping of the dryer, the inlet and outlet connections need to be fixed in position, as is
shown in the illustration.
Non-observance will cause damage.
===== Ende der Stüc kli ste =====
9.5

Connection to the cooling-water network (water-cooled)

Danger!
Compressed air and unqualified personnel!
All works must only be carried out by qualified skilled personnel.
Never work on compressed-air systems which are under pressure.
The user must ensure that the dryer is never operated with a pressure exceeding the nominal values.
Possible overpressure can be dangerous for the operator but also for the device.
The temperature and the amount of cooling water need to correspond to the limit values indicated on the type plate.
The cross-section of the connecting lines which should preferably be flexible, must be free from dust, iron rust, shards
and other contaminations. We recommend employing connecting lines (flexible hoses, vibration-inhibiting fittings etc.)
which protect the dryer against possible vibrations in the pipework.
DRYPOINT® RA 3-160
PNEUMATIG.EU - GDYNIA UL.WIELKOPOLSKA 158 -  58 622 49 22
Dryer
DRYPOINT RA 3-12
DRYPOINT RA 18-23
DRYPOINT RA 30-40
DRYPOINT RA 55-60
DRYPOINT RA 80-100
DRYPOINT RA 120-160
Installation
Ø [BSP-F]
A [mm]
1/2"
210
1"
205
1.1/4"
205
1.1/2"
235
2"
345
2.1/2"
410
15