Servicing The Fans - YASKAWA XGI 1000-65/65 Installation And Operation Manual

Commercial 1000vdc string inverter
Hide thumbs Also See for XGI 1000-65/65:
Table of Contents

Advertisement

Installation and Operation Guide SOLECTRIA XGI 1000 (Rev D)

Servicing the Fans

7.2
Three fans are user serviceable. All fans are located and accessible on the sides of the inverter. There are two
DC fans accessible on the right side of the inverter underneath the antenna, and one AC fan is accessible on
the left side at the bottom of Power Head. The AC and DC fans are different parts and cannot be interchanged.
To access the fans, remove the screw with a #2 Phillip head screwdriver and press the tabs together to remove
the assembly. See Figure 7-2 to remove the DC Fans and the AC Fan.
Screws
Tabs
Figure 7-2 DC Fans (Left) and AC Fan (Right)
On the top of the fans, there are two arrows at a 90° angle. Fan alignment is based on the arrow that points in
the direction that the fan blows, as shown on the left side in Figure 7-3.
Figure 7-3 Fan Picture with Arrow Showing the Direction of Airflow
DOCR-070733-D
Page 77 of 86