Alcatel-Lucent 1675 LambdaUnite Installation And System Turn-Up Manual page 315

Multiservice switch, release 10.5.4
Hide thumbs Also See for 1675 LambdaUnite:
Table of Contents

Advertisement

Power, software, and circuit pack installation
...................................................................................................................................................................................................................................
Legend
Circuit pack
5
Blank face plate (3 ) or any of the following circuit pack
types:
6
CTL/-, CTL/2, CTL/3T, CTL/3S, CTL/4T, CTL/4S (working)
7
EP155/EL8
8
LOXC/1, LOXC40G2/S, LOXC40G3/S
Notes:
1.
For LXC160 and LXC 320 configurations the double density versions OP2G5D and OP10D can only be
plugged into the following slots: #2, #4, #6, #8, #13, #15, #17, #19, #22, #24, #26, #28, #33, #35, #37, and
#39. The slot to the left of a slot where such a port unit is installed has to remain unequipped. Please observe
the LXC configuration rules described below.
2.
The associated ECI/155ME8 (CC109001479, unprotected configuration) or ECI/155MP8 (CC109192260,
protected configuration) interface paddle boards must be located at the back side of the subrack (upper row).
3.
The associated ECI51/MP72 interface paddle board must be located at the back side of the subrack (upper
row). More information is given in section
4.
The allowed slot position depends on the maximum switching capacity of the system (see section
configuration rules" (p.
5.
Each OP2G5/PWDM circuit pack must always be equipped with 2 OM2G5/PWDM interface modules.
Otherwise no operation would be possible.
Gigabit Ethernet and 10-Gbit/s port units
To avoid thermic stress, it is recommended not to place a 10-Gbit/s port unit directly
above a Gigabit Ethernet port unit.
Optical port unit protection
In the case of optical port protection (1+1 Linear APS / 1+1 MSP) it is recommended to
place the working port unit and the protection port unit side by side for ease of
maintenance.
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
Optical 155-Mbit/s port units (OP155...)
622-Mbit/s port units (OP622...)
2.5-Gbit/s port units (OP2G5...)
10-Gbit/s port units (OP10...)
1-Gbit/s Ethernet interface (GE1)
High density private line Gigabit Ethernet unit
(GE10PL1/1A8)
Portless TransMUX unit (TMUX2G5/1)
2
3
, EP51/EL36
or EP51/EL36B
5-51)).
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
1,5
1
3
"DS3/EC1 equipment protection rules" (p.
Software and circuit pack installation
Configuration rules
Valid slots
#01 ... #08, #12 ... #19,
#21 ... #28, #32 ... #39
Each optical board covers the following
positions:
OP155M - 1 slot
OP622 - 1 slot
OP2G5 - 1 slot
OP10 - 1 slot
GE1 - 1 slot
GE10PL1/1A8 - 1 slot
TMUX2G5/1 - 1 slot
#11
#21 ... #28, #32 ... #39
#4, #17, #18, #19, #37, and #39
5-42).