11. Long-Term Storage

WARNING : INJURY
Before performing any equipment check or maintenance, stop the engine,
and remove the engine key. A person performing the maintenance should
always keep the key.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
Allow the generator to cool before covering with the protective cover.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after
stopping the equipment, while temperature can reach extremely high.
(1) Storage Procedures
Perform the following maintenance procedures before storing this generator if it is not
going to be used for two months or more.
Remove the battery.
1
(Refer to section "8-6. Checking the Battery Replacing the Battery".)
Replace the engine oil.
2
(Refer to section "10. Inspection/Maintenance (1) Engine Oil Replacement".)
Drain the fuel from the fuel tank and filter.
(Refer to section "10. Inspection/Maintenance (5) Cleaning / Changing Fuel Filter".)
3
(Refer to section "10. Inspection/Maintenance (9) Draining Water from Fuel Tank".)
4
Remove the starter key and store in a secure location.
Clean up all generator components, and store in a dry and dust-free location. Also cover
5
when storing so that rain cannot enter through the suction or exhaust ports.
< NOTE >
Adjust the fluid of the removed battery to the appropriate level and recharge approximately every