9.

Operating Procedures

9-1. Initial Startup/Pre-Check

WARNING : SUFFOCATION FROM EXHAUST FUME
Do not operate the generator in poorly ventilated areas such as an indoors or
tunnels, as the exhaust gas of the engine contains substances that are
harmful to human health.
Do not direct exhaust fumes at pedestrians or buildings.
WARNING : INJURY
Before turning the circuit breaker to ON position, ensure that the breaker or
the switch of loads are positioned to OFF.
Operate the circuit breaker, well-communicating with the electrician by the
load side.
Close all doors and lock them during operation.
CAUTION : FIRE
Do not bring flammable items (such as fuel, gas and paint) or items that are
highly combustible near the generator as the muffler, exhaust gas and other
parts become extremely hot.
Position this generator 1m or more from walls or other hindrances, and on a
level surface.
CAUTION : INJURY
Do not operate the generator if it has been modified or any parts have been
removed.
Position the generator on a level stable surface so that it cannot slide or
move in any manner.
Before starting operation, always be sure to turn off all switches of equipment
being used and all breakers to OFF.
1
Turn every circuit breaker to OFF position.
Turn the Throttle Lever to <START POSITION>.
2
Turn the Battery Isolator to ON position.
3
Turn the starter switch to <START> position, and start the engine. In cold
environment, turn the starter switch to <Pre-heating> position, wait until the
4
pre-heating status lamp comes on, and start the engine