Figure 8-6
Signal behavior SIWAREX WP321: Sampling rate 50 Hz (unfiltered)
Figure 8-7
Signal behavior SIWAREX WP321: Sampling rate 600 Hz (unfiltered)
8.10.2

Number of support points

If no anchor points are used, the number of support points is equal to the number of load cells.
If anchor points are used in addition to load cells, the number of support points is equal to the
total number of load cells and fixed support points.
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
Scale parameters and functions
8.10 DR 10 load cell parameters
79