Quadra-Fire CB1200I-C Owner's Manual page 22

Hide thumbs Also See for CB1200I-C:
Table of Contents

Advertisement

CB1200 Pellet Insert
16. Preparing Firebox for Non-Burn Season
Frequency: At the end of the heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the firebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
Use the Touch-Up paint supplied with the appliance;
or,
Purchase paint from your local dealer.
Must use a high-temperature paint made
specifically for heating appliances.
17. Remove Baffle to Access Heat Exchanger Tubes
and Firebox Exhaust Exits
a. Open the right side access door and then open the
glass door.
b. Grasp the bottom of the baffles and pull up to dislodge
from hook attachment.
c. Use a standard screw driver to unlatch the covers
beneath the baffles of each side.
d. Re-install in reverse order.
18. Vacuum Heat Exchanger Tubes, Firebox Area and
Drop Tube
a. Use a Shop Vac to vacuum any fly ash and soot from the
heat exchanger tubes and firebox area (Figure 22.1).
b. Remove any debris that may be in the drop tube.
Exposed Heat Exchanger Tubes
Drop Tube
Remove Screws
Left & Right Access Covers
Figure 22.1 - Baffles Removed
22
19. Clean Firebox Exhaust Exits & Exhaust Blower
a. There are 2 exhaust exits at the back of the firebox on
the left and right side (Figure 22.1).
b. Using a Phillips head screwdriver remove the screws
and set aside the access covers.
c. Vacuum the 2 exhaust exits thoroughly.
d. Clean the exhaust blower blades while the
access cover on the left side is still removed
(Figure 22.3 and Figure 23.4).
Exhaust Blower
Left Access Cover
Figure 22.2
Clean-Out Door
Figure 22.3
Vent Pipe
Adapter
Clean-Out
Door
Figure 22.4
7027-805C
Vent Pipe Adapter
Exhaust Blower
Hinged Access Door
Exhaust
Convection
Blower
Blower
Firepot
Cleaning Rod
June 4, 2019