9. Cleaning Exhaust Path
Frequency: Yearly or more frequently depending on
ash build-up.
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Open the hinged access door on the left of the insert.
c. Reach in and unlatch the trap door that is connected to
the rear of exhaust blower.
d. Use a small vacuum hose attachment to clean area.
e. Re-latch and close trap door.
NOTE: There are heavy duty vacuum cleaners
specifically designed for solid fuel appliance
cleaning.
10. Cleaning the Glass
Frequency: When clear view of the fire pot is obscure
By: Homeowner
a. Appliance must be completely cool before
cleaning glass.
b. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe off with dry towel.
CAUTION
Handle glass assembly with care.
When cleaning glass:
Avoid striking, scratching or slamming glass.
Do NOT clean glass when hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white film.
Refer to maintenance instructions.
WARNING
Handle glass with care.
Inspect the gasket to ensure it
is undamaged.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass
assembly removed.
June 4, 2019
11. Door Latch Inspection
Frequency: Prior to heating season
By: Homeowner
The door latch is non-adjustable but the gasket between
the glass and firebox should be inspected periodically to
make sure there is a good seal.
NOTE: There is no gasket on the bottom of glass.
12. Door Gasket Inspection
Frequency: Prior to heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. To inspect the door rope (gasket), open the door
and see that the door rope extends approximately
1/8 inch (3mm) to 3/16 inch (9.5mm) from the door
rope channel.
c. It should show signs of compaction all the way around
the door where the rope contacts the face of the
appliance. Confirm there are no air leaks.
13. Cleaning Exhaust Blower - Requires No Lubrication
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer.
14. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer.
15. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
Frequency: Yearly or more frequently depending on
ash build-up
By: Qualified Service Technician/Homeowner
The products of combustion will contain small particles
of fly-ash. The fly-ash will collect in the exhaust venting
system and restrict the flow of the flue gases. Incomplete
combustion, such as occurs during startup, shutdown, or
incorrect operation of the room appliance will lead to some
soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at
least once every year to determine if cleaning is necessary.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
7027-805C
CB1200 Pellet Insert
21