Electrical connection
Terminals
Function
X3.8
X3.9
Pressure switch, primary circuit
P
and/or
Frost stat
or
Jumper
X3.12
"External demand" signal: Exter-
X3.13
nal starting of compressor and
or at external EA1
pumps, mixer in control mode or
extension
OPEN, changeover of the operat-
ing status of several system com-
ponents
X40
Heat pump control unit power sup-
ply:
Phase L1
X40.
X40.N Neutral conductor termi-

Controller and sensor PCB (low voltage connections)

Set the required parameters during commissioning:
See page 51 onwards.
Plug
Sensor/component
F0
Outside temperature sensor
F4
Buffer temperature sensor
F12
Flow temperature sensor, heating circuit with mixer M2/HC2
F14
Flow temperature sensor, cooling circuit: Heating circuit without mixer
A1/HC1 or separate cooling circuit SKK
F16
Room temperature sensor, cooling circuit
Required for separate cooling circuit SKK
Recommended for heating/cooling circuit without mixer A1/HC1
KM-BUS (wires interchangeable)
aVG
Use the KM-BUS distributor (accessories) if several devices are connected.
KM-BUS subscribers (examples):
Mixer extension kit for heating circuit M3/HC3
Remote control (set heating circuit allocation on the remote control)
EA1 extension, AM1 extension
Modbus (do not interchange the wires), e.g. connection for energy meter of
sVA
photovoltaic system
(cont.)
Earth conductor terminal
?
nal
Explanation
Requires floating contact:
Closed: Safety chain has continuity
Open: Safety chain interrupted; heat pump shut down
Breaking capacity 230 V~, 0.15 A
Connection:
Connected in series if 2 safety components are instal-
led
Insert jumper if no safety components are instal-
led.
Requires floating contact:
Closed: Demand
Open: No demand
Breaking capacity 230 V~, 2 mA
Note
These and further external functions (e.g. provision of
external set values) can alternatively be connected via
the external EA1 extension.
See "EA1 extension" installation instructions
Power supply 230 V~: See chapter "Power supply".
Installation sequence
Type
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
31