Commissioning, inspection, maintenance
Commissioning the system
Enable instantaneous heating water heater for DHW heating
Parameter
"DHW"
Ó
"Enable electric heaters for DHW heating 6015"
Parameters for swimming pool water heating
Parameter
"System definition"
Ó
"External extension 7010"
"Swimming pool 7008"
Parameters for ice store system
Parameter
"System definition"
Ó
"Select primary source 7030"
"External extension 7010"
Parameter
"Solar"
Ó
"Type solar control unit 7A00"
Possibly set additional parameters.
Parameter
"System definition"
Ó
"Start hysteresis solar air absorber 7031"
"Min. runtime to suppress summer mode 7035"
"Last calendar week for summer mode 7036"
Parameters for ventilation with Vitovent 200-C
Parameter
"Ventilation"
Ó
"Vitovent enable 7D00"
58
(cont.)
Setting
"1"
Setting
"1" or "3"
"1"
Setting
"1"
"2"
Setting
"2"
Setting
"0" to "500" (
"0" to "1440" min
Calendar week "1" to "53"
Setting
"2" Vitovent 200-C
0 to 50 K)