5. PRODUCT INSTALLATION

Important notes and advice:
- To make the most of your intercom panel, we recommend confi guring it (for 1 or 2 families,
1 or 2 intercoms, loudspeaker volume) before fi nal installation. To do this, it might be
necessary to connect up the system on a table to check that the settings are correct.
- If you test your product before installing it, ensure that you do not test it with the intercom
panel and the monitor in the same room to avoid the Video doorphone emitting a shrill
noise (feedback).
- Do not expose the camera lens to direct sunlight or a refl ective surface.
- We recommend running the cables through a protective sheath to protect them against
breakage and bad weather.

1. Wiring

To avoid the risk of interference and malfunctions, do not run the Video doorphone cable
through the same sheath as the electrical cables.
Warning:
Do not double up the wires to increase their section.
a. Connecting the video doorphone (monitor, intercom panel and camera, see fi g. 1, fi g. 2
or fi g. 3)
Wires to be used: 2 wires 0.75 mm
- Make sure to connect the wires in accordance with one of the wiring diagrams depending
on the desired confi guration.
- Refer to the label stuck to the back of the monitor and the back of the intercom panel.
- Confi gure the switches on the back of the intercom panel as well as the monitor interface
according to the chosen confi guration (see section 2 intercom confi guration).
b. Connecting a gate motor
- The intercom provides a dry contact (without power) to be connected to the push button
control of the automatic opener.
- Connect it directly to terminals 5 and 6 at the back of the intercom panel (no need to
observe polarity).
- The opening function is only possible if the video of the respective intercom panel is
displayed.
c. Connecting a strike plate or electric lock
Important:
The strike plate or electric lock that you are ordering must have a mechanical
memory. The strike plate current cannot exceed 1.1A.
- Connect it directly to terminals 7 and 8 at the back of the intercom panel (no need to
observe polarity).
- The opening function is only possible if the video of the respective intercom panel is
displayed.
with 80 m length or 2 wires 1.5 mm