Chapter 2 - Basic Operation

1 DIP Switch Settings

Chapter 2 - Basic Operation
1 DIP Switch Settings
NOTICE
DIP switches settings must be made only when the sub power is turned off
DIP SW
SW-1
SW-2
SW-3
SW-4
SW-5
SW-6
SW-7
SW-8
SW-9
SW-10
All DIP switches are set to OFF when shipped from the factory.
The DIP switches are located on the right face of the unit, near the bottom.
SW-1–4 : Sets the communication parameters for a serial (RS-232C) connection. When the PC-60 is connected to the computer
through the serial port, be sure that the communication parameters for SW-1 to SW-4 are set correctly, matching the
computer port settings. (Data length is fixed to 8 bits. Stop bits is 1 or 2.)
SW-5
: This sets the baud rate (transmission speed) when using a serial (RS-422) connection. Set this switch to match the
computer's communication parameters.
SW-6
: If "ROLL" has been selected using the SHEET TYPE key on the control panel, then during setup the unit detects the
front most edge of the material moves the front sensor to this front edge. This eliminates leaving any margin on the
front part of the material, for more effective use of the material.
SW-7
: Sets the amount of offset for the cutter blade. Set to OFF when using a tool with a blade offset of 0.25 mm, or to ON
when using a tool with a blade offset of 0.5 mm.
SW-8
: This "familiarizes" the unit with the material before performing printing or cutting, thereby eliminating any misalign-
ment during material feed. This is normally set to OFF (enabled).
18
Function
RS-232C Baud rate
RS-232C Parity
RS-232 Parity
RS-232C Handshake
RS-422 Baud rate
Front edge sense
Blade offset
Prefeed mode
RESERVED
RESERVED
key.
OFF
ON
9600
19200
Disable
Enable
ODD
EVEN
Hardwire
XON/XOFF
57.6K
115.2K
Disable
Enable
0.25 mm
0.5 mm
Enable
Disable