A - tap bypass screw
Remove the tap bypass screw and replace with the
correct screw. See the table for the correct bypass
screws.
Stick on label
Stick the appropriate label on to the data badge to
indicate the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the
centre hotplate burner injectors (not the Wok
burners). Lift off a burner head. Fit the pressure
gauge to the injector. Turn on and light one of the
other hotplate burners. Press in the control knob for
the burner with the pressure gauge fitted to let gas
through.
Reassemble burner top, making sure it is reassembled
in the correct way on the burner body.
Refit the control tap shield. Reconnect the wiring to
the control panel and refit the panel.
Check the appliance is gas sound.
Check operation of all the burners.
Check that the appliance is electrically safe.
Check the appliance is electrically safe and gas sound when you have finished.
INSTALLATION
A1
A2
kW
g/h
B
kW
g/h
C
kW
g/h
D
kW
g/h
A
B
C
D
31
I 2H
G20
G30
20mbar
29mbar
80
129
3.65
134
3.0
109
1.7
75
1.0
I 2E , I 2E+ , I 2H
G20
G30
20mbar
29mbar
96
54
39
38
I 3+
G31
37mbar
54
77
3.5
255
87
3.0
218
68
1.7
124
51
1.0
73
I 3+
G31
37mbar
57
40
32
28