Sw Mode Setting Via Jumper "J4; Address Setting; Address Setting Mode Via The C.i.e - Panasonic 1735 Technical Description

Alert annunciation units
Hide thumbs Also See for 1735:
Table of Contents

Advertisement

Panasonic Electric Works Nordic AB
MEW01295 Rev: 2
6.1.1
6.2
6.2.1
Technical Description Alert Annunciation Units 1735 & 1736, ver. 1.4.x
the unit will automatically be ready for the "Address setting ", see
below.

SW mode setting via jumper "J4"

An AA unit in operation
via the jumper "J4" in the unit. Activate "J4" momentarily.
When the AA unit is ready for the "SW mode setting" this is indicated
by the LED "L2" (Alarms queued). The back-light is turned on and
the following information is shown in the display:
MODE SETTING!
Type: xxxxxxxxxxxx
Continue in accordance with chapter "SW mode setting", page 16.

Address setting

After the SW mode setting, the AA unit is ready for the "address
setting".
As an alternative, an AA unit in operation
"address setting" directly via a c.i.e. menu. See the following chapter.
When the AA unit is ready for the "address setting" this is indicated
by the LED "L2" (Alarms queued). The back-light is turned on and
the following information is shown in the display:
ADDRESS SETTING
Address: XX
XX can be changed to the following:
For an AA unit, the address can be set to 00-15.
Scroll to the wanted address with the push button "P1" (black). Store
the selected address with the push button "P2" (yellow) and the unit
will automatically restart and enter its normal operation mode.

Address setting mode via the c.i.e.

A specific AA unit or all the AA units connected to the same line
(RS485) can, in normal operation, from the c.i.e. receive a command
and get ready for the "Address setting" directly. This is done via
16
If "J4" is not removed, the AA unit will not enter its normal operation
mode after the restart but start from the beginning again, ready for the SW
mode setting.
17
Or all the AA units connected to the same Ext. FBP / DU interface board
1587.
18
This is the max. no. of addresses. The max. no. of units connected to a
board is depending on the type of units and if ext. power supply is used.
19
If the unit has no SW mode, i.e. "Not selected", it will not enter its normal
operation mode after the restart but start from the beginning again, ready for
the SW mode setting.
15
will be ready for the "SW mode setting"
Change = Black
Store = Yellow
17
Change = Black
Store = Yellow
17
16
can be ready for the
18
(Default is "00".)
19