Element Inspection; Primary Element Replacement; Separator Elements Replacement; Procedure For Element Replacement - Sullair TS32 Series User Manual

Industrial rotary screw air compressor, 200-350hp/149-261kw air-cooled & water-cooled standard and 24kt
Hide thumbs Also See for TS32 Series:
Table of Contents

Advertisement

TS32 USER MANUAL
Figure 6-3: Separator Element Replacement
(I) Replacement Element P/N 02250034-085
(primary)
(II) Element Replacement Kit P/N 02250145-897
(secondary)
E
I
LEMENT
NSPECTION
1. Place a bright light inside the element to
inspect for damage or leak holes. Concen-
trated light will shine through the element,
revealing any holes.
2. Inspect all gaskets and gasket contact sur-
faces of the housing. Should faulty gaskets
be evident, correct the condition immedi-
ately.
70
3. If the clean element is to be stored for later
use, it must be stored in a clean, closed con-
tainer.
4. After the element has been installed, inspect
and tighten, if necessary, all air inlet connec-
tions prior to resuming operation.
P
E
R
RIMARY
LEMENT
1. Place the element in position over secondary
element. Replace the sealing washer and
wingnut. Tighten the wingnut so as to fully
seat the element gasket.
2. Install the cover/element assembly and
replace the wingnut.
S
E
EPARATOR
LEMENTS
Refer to Figure 6-3. The separator elements must be
changed when "Separator Maintenance Required"
message is displayed, or once a year whichever
occurs first. Follow the procedure explained below
for separator element replacement.
P
F
E
ROCEDURE
OR
LEMENT
1. Relieve all pressure from the separator and
all compressor lines prior to disconnecting
any pipes, tubing, etc.
2. Disconnect all piping connected to the sepa-
rator cover to allow removal (return lines,
service lines, etc.).
3. Loosen and remove the twelve (12) 3/4" x 3"
hex head capscrews from the cover plate.
4. Lift the cover plate from the separator using
a 3/4" jackscrew under the lifting arm post.
The lid can be pivoted to the side supported
by the lifting arm.
5. Remove the primary and secondary separa-
tor elements.
6. Scrape the old gasket material from the
cover and flange on the sump being careful
not to let the scraps fall in the sump.
7. Inspect the separator tank for rust, dirt, etc.
8. Reinsert the separator elements with gas-
kets attached into the sump taking care not
to dent them against the tank opening. DO
NOT remove grounding staples. Check
between separator element flange and tank
for continuity after torquing bolts. DO NOT
use anti-seize compound on gaskets.
SECTION 6
EPLACEMENT
R
EPLACEMENT
R
EPLACEMENT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts32 wcTs32 acTs32-200Ts32-250Ts32-300Ts32-350

Table of Contents