Pipe Sizing; Auxiliary Receiver Tank; Isolation Valves; Typical Service Air Piping - Sullair TS32 Series User Manual

Industrial rotary screw air compressor, 200-350hp/149-261kw air-cooled & water-cooled standard and 24kt
Hide thumbs Also See for TS32 Series:
Table of Contents

Advertisement

TS32 USER MANUAL
P
S
IPE
IZING
Pipes should be sized as a minimum to match the
dimensions
of
the
connection. All piping and fittings should be rated for
the discharge pressure.
A
R
UXILIARY
ECEIVER
An Auxiliary receiver tank should be installed in
systems where large demand fluctuations will occur.
I
V
SOLATION
ALVES
Install isolation valves where isolation of the
compressor from the service lines is required. These
valves should have drip legs that drain at an angle
downward from the base. A vent to the piping should
be installed downstream of the compressor outlet
connection.
60
compressor's
discharge
T
ANK
Figure 4-1: Typical Service Air Piping
When two compressors are installed to operate in
parallel with a common receiver tank, an isolation
valve and drain trap for each compressor should be
installed before the common separator/sump.
Compressors have built-in aftercoolers and are
equipped with a condensate drain located next to the
air outlet connection. A drain line should be installed
to remove the condensate, which builds up during
compressor operation. See Figure 4-1.
NOTE
Compressors not equipped with an auxil-
iary receiver tank may need to have their
response times adjusted. Contact Sullair
Customer Care for assistance.