Brother DCP-L8400CDN Service Manual page 52

Color laser
Hide thumbs Also See for DCP-L8400CDN:
Table of Contents

Advertisement

Error
Description
Codes
B000
The first or second side CIS flat
cable was detected to be not
inserted correctly.
B300
---
B400
---
B700
---
B800
---
B900
---
BA00
---
BB00
The white level value obtained
with function code 55 was
outside the specified range.
BC00
Though a fax was scanned
again after AC00 error, the
second side white or black
calibration data was not within
the normal range.
BD00
The black level value obtained
with function code 55 was
outside the specified range.
BE00
---
BF00
The first side document
scanning position sensor
detected that the document was
400 mm or more in length and
could not be fed from the ADF in
duplex feeding.
C001
Timeout occurred with access
request sent to server due to
incorrect server address,
network disconnection, or
inactive server.
C002
User authentication is
unavailable due to incorrect user
name, incorrect password, or
asynchronous date and time
between the machine and
server.
C003
Access to a file is unavailable
due to incorrect directory name,
no write permission on directory,
file write lock, or no write
permission on file.
Refer
Error
to:
Codes
2-80
C004
The current time necessary for
user authentication is
unavailable due to time not
being obtained.
C700
The memory is insufficient to
expand the data of PC-Print.
C800
The memory used to store
secure print data exceeded the
memory size for secure print
data.
C900
---
2-80
CA00
---
D100
An error occurred during modem
initialization.
2-81
D200
The machine detected that the
modem PCB was disconnected.
D800
Error occurred during touch
panel initialization.
2-81
D900
Communication between the
panel PCB and main PCB is
unavailable during touch panel
initialization.
DA00
After the initialization of the
panel PCB, no response was
2-81
sent from the panel PCB for a
period of time.
DB00
USB communication between
the main PCB and panel PCB is
unavailable.
2-82
E000
Some ROM checksum error
occurred.
E100
Program error.
E400
The failed DIMM is installed, or
the DIMM is not installed
2-82
correctly.
E500
Error occurred when DRAM on
the main PCB ASSY was
accessed.
E600
Error occurred during writing to
2-82
EEPROM on the main PCB
ASSY.
2-22
Description
Confidential
Refer
to:
2-82
2-83
2-83
2-83
2-83
2-84
2-84
2-84
2-84
2-85
2-85
2-85
2-85
2-85

Advertisement

Table of Contents
loading

Table of Contents