Note:
- After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
- When connecting flat cables, do not insert them at an angle. After insertion, check that
the cables are not at an angle.
<How to fold the Modem flat cable>
A4 model
40±1 mm
18±1 mm
<To be connected
45°
to Modem PCB>
Supporting plate
Legal model
<To be connected
to Modem PCB>
Supporting plate
157±2 mm
155±2 mm
45°
Fig. 3-177
138±2 mm
128±2 mm
45°
Fig. 3-178
3-131
Fold down
Fold back
76±1 mm
20±1 mm
45°
45°
Fold down
Fold back
82±1 mm
20±1 mm
45°
Supporting plate
11±1 mm
<To be connected
to Main PCB>
Supporting plate
10±1 mm
<To be connected
to Main PCB>
Confidential