Vertical streaks
Step
1
Dirt in the paper feed system
2
Installation failure of each FG
wire and/or FG plate
(Grounding is not performed
correctly.)
3
Dirt on the exposure drum
4
Dirt on the cleaner pinch roller
of the fuser cover
5
Dirt on the fuser unit
6
Laser unit failure
< User Check >
- Clean the corona wire of all four colors on the drum
unit.
- Return the cleaning tab of the corona wire to the
position.
- This symptom might stop occurring after making
several prints.
- Refer to the User's guide and remove the dirt on the
exposure drum using a cotton swab.
- Replace the drum unit with a new one.
- Replace the toner cartridge with a new one.
- Wipe the scanner windows of the laser unit with a soft,
lint-free cloth.
Cause
Wipe dirt off.
Retighten the screws of each FG wire and/or
FG plate. Repair the bend of the tray ground
spring of the paper tray.
(See the figure below.)
Perform drum cleaning.
(Refer to
Replace the cleaner pinch roller S ASSY.
Replace the fuser unit.
Replace the laser unit.
Tray ground spring
Fig. 2-13
2-104
Remedy
"2.2 Drum Cleaning" in Chapter
Paper tray
<Bottom of paper tray>
5.)