Overview - Omega Engineering DFG35 Series User Manual

Digital force gauges
Table of Contents

Advertisement

DFG35 Digital Force Gauges

1 OVERVIEW

1.1 List of included items
DFG35-0.12 –
Qty.
DFG35-20
1
12-1049
1
08-1022
1
08-1026
1
G1024
1
G1026
1
G1025
1
G1027
1
G1029
1
G1028
1
N/A
1
-
1
09-1165
1
-
1.2 Safety / Proper Usage
Caution!
Note the force gauge's capacity before use and ensure that the capacity is not exceeded.
Producing a force greater than 150% of the gauge's capacity can damage the internal load cell. An
overload can occur whether the gauge is powered on or off.
Typical materials able to be tested include many manufactured items, such as springs, electronic
components, fasteners, caps, films, mechanical assemblies, and many others. Items that should not be
used with the gauge include potentially flammable substances or products, items that can shatter in an
unsafe manner, and any other components that can present an exceedingly hazardous situation when
acted upon by a force.
The following safety checks and procedures should be performed before and during operation:
1. Never operate the gauge if there is any visible damage to the AC adapter or the gauge itself.
2. Ensure that the gauge is kept away from water or any other electrically conductive liquids at all
times.
3. The gauge should be serviced by a trained technician only. AC power must be disconnected and
the gauge must be powered off before the housing is opened.
4. Always consider the characteristics of the sample being tested before initiating a test. A risk
assessment should be carried out beforehand to ensure that all safety measures have been
addressed and implemented.
5. Wear eye and face protection when testing, especially when testing brittle samples that have the
potential to shatter under force. Be aware of the dangers posed by potential energy that can
accumulate in the sample during testing. Extra bodily protection should be worn if a destructive
failure of a test sample is possible.
Part No.
DFG35-50 –
DFG35-200 –
DFG35-100
DFG35-500
12-1049
12-1049
08-1022
08-1022
08-1026
08-1026
G1024
G1031
G1026
G1033
G1025
G1032
G1027
G1034
G1029
G1036
G1038
G1035
G1039
G1037
Description
Carrying Case
AC adapter body with US, EU, or UK prong
Battery (inside the gauge)
Extension rod
Cone
Chisel
V-groove
Flat
Hook
Coupling
Certificate of calibration
USB cable
Resource CD (USB driver, user's guide)
User's Guide