4-1 Installation Conditions

Decelerator Installation Conditions

Using Another Company's Decelerator (Reference)
If the system configuration requires another company's decelerator to be used in combination
with an OMNUC G5-series Servomotor, select the decelerator so that the loads on the motor
shaft (i.e., both the radial and thrust loads) are within the allowable ranges. (Refer to
Characteristics on page 3-2 for details on the allowable loads for the motors.)
Also, select the decelerator so that the allowable input rotation speed and allowable input
torque of the decelerator are not exceeded.
4
4-5
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)