4 System Design
4-1

Installation Conditions

This section describes the installation conditions for the Servo Drive and Linear Motor.
4-1-1
Installation Conditions
Space Conditions around Servo Drives
Install the Servo Drives according to the dimensions shown in the following illustration to ensure proper
dispersion of heat from inside the drives and convection inside the panel. If the drives are installed side
by side, install a fan for air circulation to prevent uneven temperatures inside the panel.
40 mm min.
Capacity
100 W to 5 kW
• Drives of 100 V or 200 V with a capacity of 750 W max. can be installed side by side with a 1-mm
clearance (W in above illustration).
To provide electrical continuity, remove any paint from the surface on which you are installing G5-series
Servo Drives.
Also, it is recommended that you apply conductive plating if you are making the mounting bracket
yourself.
Mounting Direction
Mount the drive perpendicular on the panel so that the model number reads normally.
Operating Environment Conditions
The environment in which drives are operated must meet the following conditions. Drives may
malfunction if operated under any other conditions.
• Operating ambient temperature: 0 to 55°C (Take into account the following temperature rises in the
individual drives themselves.)
• Operating ambient humidity: 20% to 85% max. (with no condensation)
• Operating ambient atmosphere: No corrosive gases.
• Altitude: 1,000 m max.
4 - 2
Fan
Fan
Drive
Drive
Drive
A
B
C
W
W
Dimensions [mm]
10 mm min.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
100 mm min.
Air
Side of
Drive
100 mm min.
Air

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents