Installation Conditions; Servo Drive Installation Conditions - Omron R88M-K Series User Manual

Ac servomotors/servo drives with built-in ethercat communications
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

4-1 Installation Conditions

4-1 Installation Conditions

Servo Drive Installation Conditions

Space Conditions around Servo Drives
Install the Servo Drives according to the dimensions shown in the following illustration to ensure
proper dispersion of heat from inside the drives and convection inside the panel. If the drives are
installed side by side, install a fan for air circulation to prevent uneven temperatures inside the
panel.
4
Mounting Direction
Mount the drive perpendicular on the panel so that the model number reads normally.
Environment Operating Conditions
The environment in which drives are operated must meet the following conditions. Drives may
malfunction if operated under any other conditions.
Drives of 100 V or 200 V with a capacity of 750 W max. can be installed side by side with a 1-mm
clearance (W in above illustration). However, the specifications for operating ambient temperature
depends on the drive.
4-1
Fan
Drive
Drive
A
B
W
40 mm min.
W = 10 mm min.
Ambient operating temperature: 0 to 55°C (Take into account the following temperature rises
in the individual drives themselves.)
Operating humidity: 90% max. (with no condensation)
Operating atmosphere: No corrosive gases.
Altitude: 1,000 m max.
Drive A:
0 to 50°C
Drive B:
0 to 40°C
Drive C: 0 to 45°C
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
100 mm min.
Fan
Drive
C
W
100 mm min.
Air
Side
of
Drive
Air

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents