Installation sequence
Electrical connections
Clamps
Function
X3.8
X3.9
Primary circuit pressure switch
P
and/or
Frost stat
or
Jumper

Controller and sensor PCB (sensors)

Set the required parameters during commissioning:
See page 39 onwards.
Plug
Sensor/component
F0.1/F0.2
Outside temperature sensor
F0.2/F0.3
Radio clock receiver (on site)
F4
Buffer temperature sensor
F6
Cylinder temperature sensor, top
(X25.5/X25.6)
F7
Cylinder temperature sensor, bottom
(X25.7/X25.8)
F11
Contact humidistat 24 V
Note
If the contact humidistat of the NC-Box is used when cooling, set jumper,
otherwise the heat pump will not start (message "CA Protectn device prim-
ry").
F13
Flow temperature sensor, system (downstream of the heating water buffer
cylinder and external heat generator)
F14
Flow temperature sensor, cooling circuit: Heating circuit without mixer
A1/HC1 or separate cooling circuit SKK
F16
Room temperature sensor, cooling circuit
Required for separate cooling circuit SKK
Recommended for heating/cooling circuit without mixer A1/HC1
F20
Boiler water temperature sensor, external heat generator
KM-BUS (wires interchangeable)
aVG
Use the KM-BUS distributor (accessories) if several devices are connected.
KM-BUS subscribers (examples):
Extension kit, mixer for heating circuit M2/HC2
Remote control: Set the heating circuit allocation on the remote control.
EA1 extension, AM1 extension
Modbus 2 (wires not interchangeable)
sVA
Connection for photovoltaic system energy meter
J3
Jumper for terminator, Modbus 2
Terminator active (delivered condition)
Terminator not active
J4
Jumper for setting master/slave, Modbus 2
Heat pump control unit is slave.
Heat pump controller is master (delivered condition).
24
(cont.)
Explanation
Requires floating contact:
Closed: Safety chain has continuity
Open: Safety chain interrupted; heat pump shut down
Breaking capacity 230 V~, 0.15 A
Connected in series if 2 safety components are instal-
led
Insert jumper if no safety components are instal-
led.
Type
NTC 10 k
Ω
DCF
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω