800
INTENDED USE
WARNING
Worker exposure level should be checked
upon installation and periodically
thereafter to be certain it is within
applicable federal, state and/or local
regulations and guidelines (i.e. OSHA PEL and ACGIH
TLV limits in the U.S.).
The Statiflex 800 is intended to be used with Lincoln Electric
extraction arm(s) and fan(s). For information on use of these
products, refer to the instruction manuals of the corresponding
arm and/or fan.

FILTER MAINTENANCE INDICATOR

The Statiflex 800 is provided with a Filter Maintenance Indicator
(See Figure B.1). When using the filter unit, regularly check the
Filter Maintenance Indicator when the fan is running. The indicator
slowly moves from green to red as filter cartridge becomes
saturated or clogged.
FIGURE B.1
0
2
4
GREEN ZONE
When the Filter Maintenance Indicator is red, replace the
LongLife
®
filter cartridge. See Filter Replacement for description.
ATTENTION
The Filter Maintenance Indicator only
functions when the fan(s) is/are in operation
and the system is properly configured.
WARNING
Saturation or clogging of the filter
cartridge results in a decrease of the
extraction capacity which could result in a
higher localized concentration of welding
fumes.
When the Filter Maintenance Indicator is entirely red while one fan
is in operation, replace the LongLife filter cartridge. Filter
replacement is described in Maintenance Section.
8
6
RED ZONE
YELLOW ZONE
0
6
2
START/STOP:
MANUAL CLEANING
CLEAR: ALARM
Manual Clean Button
B-3
OPERATION
FIGURE B.2
8
CLEANING
ALARM
Alarm Lamp