INSTALLATION

For information on installation of fume extrac-
tion arm(s) and extraction fan(s), refer to the
corresponding manuals.
NOTE: Mount the Statiflex 800, extraction fan(s) and fume
extraction arm(s) as close as possible to the source of welding.

STATIFLEX 800 SINGLE ARM

NOTE: In the standard configuration of the Statiflex 800 Single
Arm system, the filter unit is positioned on the right side of the
fan. However, it may be mounted on either side, as long as the
connection hose reaches from the outlet of the fan to the inlet of
the Statiflex 800.
WARNING
The installer is responsible for following
federal, state and local safety codes and
regulations.
Before drilling, verify locations of existing
gas, water or electrical conduits.
Step 1
Refer Figure A.1, Based on the available space / space
requirements for the install, decide the locations for the Fan
Mounting (Refer Instruction manual attached with fan) and SF800.
Remove the wall mount bracket attached to the filter unit on the
back side. Loosen the screws (2 places) on the bottom sides and
take the wall mount bracket out. Do not completely remove the
screws. These screws are required for securing the unit to the
mounting bracket when installed on the wall.
Carefully review and follow the distances mentioned in the set-
up diagram Figure A.7 or A.8. Install the wall mount bracket to
the wall. Use appropriate screws (not included) to attach the
bracket to wall. Use the slots (6 places) provided in the mounting
bracket to attach the screws (6 places required).
FIGURE A.1
ATTENTION
Use adequate mounting hardware for installing the unit,
corresponding with the type of wall. Be aware, the weight
of the unit when unpacked is approx. 260 LBS (118 kg).
As filter saturates it will increase in weight.
Step : 2
Refer Figure A.2, Remove the inlet plate and replace it with
Inlet flanges. Re-use the same screws to assemble the inlet
flange.
Step : 3
Refer Figure A.3, Hang the Filter Unit on to the wall mount
bracket (inset A), and secure it by tightening the two bolts
loosened in step 1 (inset B) from both sides on to the wall
mount bracket.
A
A-4
INSTALLATION
FIGURE A.2
FIGURE A.3
B