Automation Controlled Probe System - Dukane AiM iQ Series User Manual

Automation in mind ultrasonic power supply
Hide thumbs Also See for AiM iQ Series:
Table of Contents

Advertisement

iQ Series AiM
Automation in Mind,
AC BREAKER
PE
A
D
AC POWER ENTRY
Figure 2-1 Generator - Bottom View (Vertical Panel
Automation Controlled Probe
System
1. Ground the generator chassis using the supplied
14-Gauge wire, and attach it to the grounding stud:
in Figure 2-1.
A
2. Recommended – Ground the probe support. This is a
user–supplied 14-Gauge wire. This is required if the
probe support does not have a good earth ground
through the machine.
3. Input Cable/Output Cable - Attach the automation
control cable from the user–supplied automation
equipment to the system input HD-26 connector, J5
on the I/O panel:
B
4. Attach the high voltage coaxial cable from the probe
to the ultrasound output connector J1:
in Figure 2-1.
C
5. Connect the AC power cord to the generator IEC
power inlet connector, and plug the other end into
an approved AC outlet:
in Figure 2-1.
D
Page 10
Ultrasonic Power Supply User's Manual
Continued from Previous Page
Mount Chassis)
in Figure 2-1.
C
ULTRASOUND
Dukane Manual Part Number 403-611-00
SYSTEM I/O
B
OPTIONS SLOT
MPC
EtherNet/IP Modbus TCP/IP
USB