Power Cords; Automation Controlled System - Dukane iQ Series AL User Manual

Ultrasonic power supply
Table of Contents

Advertisement

Power Cords

200/240 Volt Systems
The IEC AC power inlet connector mounted on the rear
panel requires a properly configured IEC compliant power
cord.
The 200/240 AC power cords supplied with the
generators are matched to the ultrasonic output power
rating and the continent of specified use. See Table 3-I.
Continent of Use
North America
Europe
India
Table 3- I Standard IEC AC Power Cord Part Numbers
100/120 Volt Systems
The power cord (including strain relief) supplied with the
100/120 AC systems is permanently attached to the rear
of the generator. Units with this power cord are for use in
North America or Japan.
Dukane Manual Part No. 403-583-00
Power Cord
Power
Part Number
200 - 1541
240V, 10A
200 - 1542
240V, 10A
200 - 1624
240V, 10A
(North America or Japan)

Automation Controlled System

Step 1. Ground the generator chassis using the supplied
14-Gauge wire, and attach it to the grounding
stud:
in Figure 3 -3.
C
Step 2. Optional – Ground the probe support. This is a
user–supplied 14-Gauge wire.
Step 3. Input/Output Cable - Attach the automation
control cable from the user–supplied automa-
tion equipment to the system HD-15 connector,
INPUTS/OUTPUTS on the rear panel:
Figure 3 -3.
Step 4. Attach the high voltage coaxial cable from the
probe to the ultrasound output connector,
Figure 3 -3.
Step 5. Connect the AC power cord to the generator
IEC power inlet connector, and plug the other
end into an approved AC outlet:
in Figure 3 -3.
A
Section 3 – Installation
in
B
in
D
Page  