2-2. Refrigerator Sensor Error (Er rT)
Symptom
1. Er RT
1. Check for a loose connection
2. Check Sensor Resistance
CON7
11
CON7
11
Check Point
th
th
pin ~ 12
pin
Resistance [Ω]
th
th
pin ~ 12
pin
23ºF / -5ºC
32ºF / 0ºC
41ºF / 5ºC
50ºF / 10ºC
59ºF / 15ºC
63
CON7
Resistance [Ω]
Short
0
Open
OFF
Other
Normal
38k
30k
24k
19.5k
16k