Bit →
Bit 7
Byte
channel
0/1
10...15/
58...63
10/58
Set output (DQ1):
0000
: Use by user program
B
0001
: Between comparison value and high limit;
B
Measuring: Measured value >= comparison value
0010
: Between comparison value and low limit;
B
Measuring: Measured value <= comparison value
0011
: At comparison value for a pulse duration
B
0100
: Between comparison value 0 and 1
B
0101
: After set command from CPU until comparison
B
value
0110
: Not between comparison value 0 and 1
B
0111 to 1111
: Not permitted
B
11/59
Count direction (DQ1):
00
: Not permitted
B
01
: Up
B
10
: Down
B
11
: In both directions
B
12/60
13/61
14/62
15/63
16/64
16/64
Behavior of
Edge selection (DI0):
counter
00
value after
01
Capture
3
10
(DI0):
0
: Contin-
11
B
ue counting
edge
1
: Set to
B
start value
and contin-
ue counting
Technology module TM PosInput 2 (6ES7551-1AB00-0AB0)
Manual, 06/2018, A5E03982218-AB
B.1 Parameter assignment and structure of parameter data record
Bit 6
Bit 5
Count direction (DQ0):
00
: Not permitted
B
01
: Up
B
10
: Down
B
11
: In both directions
B
WORD: Value range in ms/10: 0 to 65535
WORD: Value range in ms/10: 0 to 65535
: Not permitted
5
B
: At rising edge
B
: At falling edge
B
: At rising and falling
B
Bit 4
Bit 3
Behavior of a DQ
Set output (DQ0):
0000
: Use by user program
B
0001
: Between comparison value and high limit;
B
Measuring: Measured value >= comparison value
0010
: Between comparison value and low limit; Meas-
B
uring: Measured value <= comparison value
0011
: At comparison value for a pulse duration
B
0100
: Not permitted
B
0101
: After set command from CPU until comparison
B
value
0110 to 1111
Reserved
2
Pulse duration (DQ0):
Pulse duration (DQ1):
Behavior of DI0
Select level
Reserved
2
(DI0):
0
: Active
B
with high
level
1
: Active
B
with low
level
Parameter data record
Bit 2
Bit 1
: Not permitted
B
Reserved
Substitute
2
value for
DQ1
D
D
Set function of DI (DI0):
000
: Gate start/stop (level-triggered)
B
001
: Gate start (edge-triggered)
B
010
: Gate stop (edge-triggered)
B
011
: Synchronization
3
B
100
: Enable synchronization at signal N
B
101
: Capture
B
110
: Digital input without function
B
111
: Not permitted
B
Bit 0
Substitute
value for
DQ0
3