Normal/Reverse Rotation And Electric Brake - Panasonic MGSDB2 Instruction Manual

Speed controller for small geared motors
Hide thumbs Also See for MGSDB2:
Table of Contents

Advertisement

4. Wiring diagram

Normal/reverse rotation and electric brake

<Precautions>
• The number of start/stop operations should be 6/min. or less.
25 W or less
2
1
CW
Spark killer
7
CCW
C1
SW2
R1
8
RUN
STOP
R2
External
3
STOP
braking
6
resistor
SW3
RUN
4
5
Pin No.
SW1, SW2
100 V supply system
SW4, SW5
200 V supply system
SW3
Spark killer R1+C1
External braking resistor R2
For option, refer to p. 29, p. 30 onward.
SW1
Feed motor
rated voltage
White
SW4
Gray
Motor
CW
Black
SW5
CCW
Capacitor
Pink
TG
Pink
Rotating direction viewed
from shaft end
CW
Clockwise
CCW Counterclockwise
5 A or more at 125 VAC
5 A or more at 250 VAC
10 mA at 10 VDC
DV0P008A (option)
DV0P003 (option)
– 24 –
40 W or higher
2
1
External
CCW
braking
resistor
CW
R2
CCW
RUN
STOP
8
C1
CW
SW2
R1
Spark killer
7
3
STOP
6
Pink
SW3
RUN
4
5
Pin No.
<Precautions>
When SW2 and SW3 are
switched from RUN to STOP,
electric braking is applied for
approx. 0.5 sec., and the motor
stops instantly.
Difference in switching time
between SW2 and SW3 must be
0.1 sec. or smaller.
<Precautions>
If SW2 is in RUN position while SW3 is in STOP, abnormal operation
occurs (full speed rotation for a short time; or if SW3 is in RUN
position while SW2 is in STOP, motor temperature rises excessively.
<Precautions>
Never attempt to change direction (SW4, SW5) while motor is
running or electric brake is being applied.
SW1
Feed motor
rated voltage
SW4
Gray
SW5
Black
Motor
Capacitor
White
TG
Pink
Braking
Stop
Normal
Reverse
SW1
ON
SW2
STOP
SW3
RUN
RUN
SW4
SW5
CW
CCW
0.7 sec. or longer
SW1: Power switch
SW2: RUN/STOP switch
SW3: Braking start switch
SW4, SW5: Normal/Reverse selector
switch
– 25 –
Braking

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgsdb1Mgsda1Mgsdb2 seriesMgsd series

Table of Contents