Pages Details; Insertion Of The Password; Description; Components Of The Page - ABB SACE Emax 2 Series Instructions For Use Manual

Low voltage air circuit-breakers
Table of Contents

Advertisement

2 - Pages details

3 - Insertion of the password

Description The page where the password is entered is open, if a parameter to be entered, or the Test menu have been
Components of the page The page appears as follow:
9 | © 2018 ABB | 1SDH001316R0002 - ECN000086018 - Rev. C
Details related to this chapter are available in the manual
available on the website ABB library.
selected, or if the password must be changed.
NOTE: insertion of the password is requested, if:
• The password has never been inserted.
• After programming has been cancelled.
• After a few minutes of inactivity.
The password is composed of five digits, each of which can have a value from 0 to 9.
The default value is "00001", and it must be modified after the first switch-on in order to prevent access by
unauthorized personnel.
In order to modify the password, from the menu Settings, you need to select System - New Password.
It is possible to disable the password by inserting "00000" as new password .
Figure 5
The following table provides a description of the various areas of the page:
Pos.
Function
A
Cancels the operation, and opens the start menu.
B
It shows the name of the page
C
Keys to increase and decrease the corresponding digit.
D
It displays the digits of the password.
Confirm key:
• Confirmation after inserting a digit in a position from 1 to 4 will automatically bring you to the
E
next digit.
• When the fifth digit is confirmed, the entire password is confirmed and the selected page is
opened.
NOTE:
• If you are changing the password, after the first confirmation of the new password, the page
opens again for the reconfirmation.
• In the case of an incorrect password, the message "Wrong Password" appears for approximately
3 seconds, and the page for insertion of the password opens again.
• There is no limit to the number of incorrect passwords that you can insert.
• If the password is lost, see the document
1SDH001330R0002
A
B
Password
0
*
*
*
Confirm
E
1SDH001501R0002
ABB | SACE Emax 2
(Emax 2 engineering manual)
C
*
D
or contact ABB
Ekip Touch protection trip unit | 2 - Pages details

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents