ERROR CODES
Possible Causes
Error Code 1 - Over Temperature - The measured
temperature has exceeded the overtemp set point.
Error Code 2 - No Start - The grill did not reach the warm
condition set point before the timer expired (15 Min.)
Error Code 3 - Power Failure - The power failed while the
grill was operating and the grill temperature was below the
warm set point when power was returned.
GRILL WON'T IGNITE
Possible Causes
Verify power at the electrical outlet
If Power Cord is connected to a GFI (Ground Fault
Interrupter), check and reset if necessary
GRILL ENTERS SHUTDOWN MODE UNEXPECTEDLY
Possible Causes
The convection blower is overheating and tripping the
internal temperature shutoff.
The grill is being left on the highest setting for extended
periods of time.
Fuel other than wood pellets is being burned in the grill.
Power surge or brown out situation.
Thermocouple is malfunctioning.
AFTER GRILL HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS
Possible Causes
Grill is dirty, which restricts airflow through the burnpot.
Burnpot holes are blocked.
Blockage in air intake pipe.
Combustion blower is not spinning fast enough.
Bad Pellets.
WARNING: Never leave the grill unattended while operating.
Disconnect the grill from its power source when not in use.

Troubleshooting

Possible Remedies (Unplug grill first when possible)
Call Customer service (800) 750-2723.
Visually inspect the ignition system. Try to start the grill again. If
the grill fails to start a second time call customer service (800)
750-2723.
Press the power and the prime button at the same time to
resume standard operation.
Possible Remedies (Unplug grill first when possible)
Plug another electrical device into that outlet to confirm power
Reset the GFI and initiate startup procedure
Possible Remedies (Unplug grill first when possible)
Clean any dust off of the windings and fan blades. If oiling the
blower does not help, the blower may be bad.
If operating the grill on the highest heat setting, the room
temperature could increase enough and lead to potential
overheating situations. If this happens, try operating at a lower
heat setting.
This pellet grill is designed and tested to use cooking wood
pellets. Check for signs of fuel other than wood pellets. No
other types of fuel have been approved for this pellet grill. If
there are signs of other types of fuel being used, stop using
them immediately.
A power surge, spike, or voltage drop could cause the
thermocouple to malfunction. Use a surge protector
If the other items check out OK, replace the thermocouple.
Possible Remedies (Unplug grill first when possible)
Follow all cleaning procedures in the maintenance section of
the owner's manual.
Remove the burnpot and thoroughly clean it.
Visually inspect the air intake that leads into the burnpot for
foreign material.
Clean fan blades and inspect bearings for wear. Ensure the
fan is free of any obstructions.
The brand of pellets or the batch of pellets that are being used
may be of poor quality. If possible, try a different brand of
pellets. You might also want to try a brand that is made from
a different type of wood (softwood vs. hardwood). Different
woods have different characteristics when being burned.
-13-