7.1.2

Status and error displays

"DIAG" LED
State
"BUS" LED
State
SIRIUS 3RW5 EtherNet/IP communication module
Manual, 05/2019, A5E45131885002A/RS-AA/001
Meaning
There is an EtherNet/IP connection between the 3RW5 communication
module and the controller.
Lights up green
Standby:
The 3RW5 soft starter is not configured.
Flashes green
The 3RW5 communication module is not parameterized.
Irreversible error
Error can only be acknowledged by switching the control supply voltage
Lights up red
off and on again.
Reversible error (e.g. loss of the IP address due to an address conflict)
Firmware update
Flashes red
No supply voltage available.
Off
Meaning
At least one CIP connection and no timeout of the exclusive owner
connection.
Lights up green
An IP address is configured.
No CIP connection
Flashes green
IP address conflict
Firmware update
Lights up red
Timeout of an exclusive owner connection:
Control was stopped without connection termination.
Flashes red
Interruption of the Ethernet communication.
Device has not yet received an IP address.
Off
No supply voltage available.
Messages and diagnosis
7.1 LED display
53