TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mains frequency:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Output holdtime:
Mounting height:
Temperature range:
Humidity:
Degree of protection:
Dimensions:
Materials:
Weight:
Cable lenght:
Conformity:
Technology:
Transmitter frequency/wavelength:
Transmitter power density:
Detection mode:
Detection field:
Min. detection speed:
Reaction time:
Tilt angle:
Specifications are subject to changes without prior notice.
Measured in specific conditions
CONDOR / -XL
MOTION AND PRESENCE SENSOR
FOR AUTOMATIC INDUSTRIAL DOORS
CONDOR: for normal to high mounting (3.5 - 6 m)
CONDOR XL: for low mounting (2 - 3.5 m)
12V to 24V AC ±10%; 12V to 24V DC +10% / -3%
< 3.5 W / VA
50 to 60 Hz
2 relays (free of potential change-over contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 42 VA (AC)
0.5 s
CONDOR: 3.5 m - 6 m; CONDOR XL: 2 m - 3.5 m*
from -30 °C to + 60 °C (except for cold storage)
0 - 95% non condensing
IP65
127 mm (L) x 102 mm (H) x 96 mm (W)
ABS and polycarbonate
400 g
10 m
EN 300 440-2 V1.4.1; EN 301 489-1 V1.9.2; EN 301 489-3 V1.6.1;
EN 62311; EN 62479; EN 50581
microwave doppler radar
24.150 GHz
< 5 mW/cm²
motion
CONDOR: 4 x 5 m ; CONDOR XL: 4 x 2 m**
5 cm/s
100 ms
-8° - 22° (relative to sensor front face)
*
depending on size and nature of target
** measured at 30°, field size 9, mounting height: 5 m, XL: 3.5 m
*** zone detected by spotfinder, slightly bigger than actual detection field
1.
push buttons
2.
infrared detection
3.
radar angle
4.
radar detection
5.
sensor angle
6.
bracket
7.
cable
active infrared
875 nm
< 250 mW/m²
motion & presence
4 m x 4 m (emitting spots***)
5 cm/s to activate detection
250 ms
15° - 45°
5
6
7
1

Advertisement

Table of Contents
loading

Summary of Contents for BEA CONDOR

  • Page 1 30 W (DC) / 42 VA (AC) Output holdtime: 0.5 s Mounting height: CONDOR: 3.5 m - 6 m; CONDOR XL: 2 m - 3.5 m* Temperature range: from -30 °C to + 60 °C (except for cold storage) Humidity:...
  • Page 2: Safety Instructions

    LED- SIGNAL Motion detection LED flashes Value indication Presence detection LED flashes quickly Parameter indication LED is off Setup DIMENSIONS (in mm) Wall mounting Ceiling mounting Bracket dimensions SAFETY INSTRUCTIONS The warranty is void if Only trained and After installation, Test the good functioning unauthorized repairs qualified personnel...
  • Page 3: How To Use The Remote Control

    HOW TO USE THE REMOTE CONTROL If the red LED flashes quickly after unlocking, enter an After unlocking, the red LED access code from 1 to 4 digits. flashes and the sensor can be If you do not know the access code, cut and restore adjusted by remote control.
  • Page 4: Sensor Angle

    CONDOR / CONDOR XL MOUNTING Remove the bracket from the sensor. Position the sensor on the Drill 2 holes accordingly. bracket and fasten the screws. Fix the bracket firmly. WIRING Connect the wires to the door controller. 12-24 V POWER SUPPLY Choose between NO and NC contact.
  • Page 5 CONDOR / CONDOR XL RADAR FIELD By turning this screw, the Adjust the field size. Choose the right p. 6 p. 6 radar field angle is reduced or detection filter for your increased (from -8° to +22°). application. The total angle is the sum of the sensor angle and the radar field angle.
  • Page 6 POSSIBLE REMOTE CONTROL SETTINGS > > > > FIELD SIZE DETECTION FILTER Detection only of VEHICLES MOVING TOWARDS THE SENSOR Detection of ALL TARGETS (pedestrians and parallel traffic are not detected + immunity filter) (pedestrians and parallel traffic are detected) if total angle is ±...
  • Page 7: Troubleshooting

    TROUBLESHOOTING The door remains The sensor power is off. Check the wiring and the power supply. closed and the LED is OFF. Launch a new setup. The infrared power emission The infrared sensor Step out of the detection field! is too low according to the does not react.
  • Page 8 BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM BEA hereby declares that the CONDOR is in conformity with the basic requirements and the other relevant provisions of the directives 2014/53/EU and 2011/65/EU.