Download Print this page

General Description - American Standard SELECTRONIC 606B2 Series Installation Instructions Manual

Concealed toilet flush valve 1.1. 1.28 & 1.6 gpf, exposed back spud/concealed back spud/top spud

Advertisement

Fig. 1
Roughing-in
Dimensions
160mm
(6-1/4)
160mm
(6-1/4)
OVERRIDE
BUTTON
SENSOR
SUPPLY
(1) NPT
-C-L-
108mm-134mm
(4-1/4 TO 5-1/4)
*-C-L-
152mm MIN.
(6) MIN.
TOP OF
FIXTURE
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
"
(152mm) min.
above fixture. Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2.
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
25mm (1) MAX.
WALL THICKNESS
FINISHED
WALL
127mm X 127mm
(5X5 CUTOUT
FOR BOX)
TOP SPUD
TOILET
70mm
(2-3/4) DIA.
51mm
(2)
400mm MAX.
(15-3/4) MAX.
FINISHED
FLOOR
DETECTION ZONE
400mm-800mm
(Factory Setting: 400mm)
15˚
FOR LOCATION OF INLET SUPPLY ON BACK INLET
FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
360mm MAX.
(14-3/16) MAX.
EXPOSED BACK
SPUD TOILET
450mm MAX.
(17-3/4) MAX.
128mm MAX.
(5) MAX.
51mm
(2)
Fig. 2
2
1
4
5
7
• Flush all water lines prior to operation (See Step 3).
Dirt and debris can cause flush valve to run continuously.
• With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
3

GENERAL DESCRIPTION:

SELECTRONIC
PROXIMITY TOILET
®
FLUSH VALVE
Concealed Flushometer for 1-1/2"
Top Spud Fixtures
CAUTION: Use only American Standard
supplied transformers and cable sets.
Using non-AS supplied cables, or cutting,
splicing or modifying any components will
void the warranty.
REFER TO FIXTURE INSTRUCTION SHEET.
-C-L-
CONCEALED BACK
SPUD TOILET
*-C-L-
152mm MIN.
240mm MAX.
(6) MIN.
(9-1/2) MAX.
TOP OF
FIXTURE
51mm
(2)
FINISHED
FLOOR
3
10'
6
9
10
M965640 Rev. 1.4 (11/17)
TOP OF
FIXTURE
FINISHED
FLOOR
8

Advertisement

loading