Fig. 1
Roughing-in Dimensions
72mm
(2-7/8)
116mm
(4-5/8)
MANUAL
OVERRIDE
BUTTON
*CRITICAL
LEVEL
-C-L-
293mm
(11-1/2)
*-C-L-
165mm
(6-1/2)
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Water Closet
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
DETECTION ZONE
(15-3/4 TO 31-1/2)
SUPPLY
DN 25mm
(1" I.P.S.)
115mm-134mm
(4-1/2 TO 5-1/4)
409mm
(16-1/8)
FOR 1-1/2" TOP
SPUD FIXTURES
"
(152mm) above
400mm-800mm
FINISHED WALL
57mm
(2-1/4 MIN.)
15˚
Fig. 2
1
5
7
• Flush all water lines prior to operation (See Step 4). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
2

GENERAL DESCRIPTION:

SELECTRONIC™
PROXIMITY TOILET
FLUSH VALVE
Exposed Flushometer
for 1-1/2" Top Spud Fixtures
Exclusive, self cleaning piston-type
flush valve with proximity operation
and manual override. Operates on
DC (battery) power. Recommended
operating pressure 25 psi (flowing)
to 80 psi (static). Can install left or
right-handed. Detection Zone can
also be adjusted manually, or with
optional remote control.
Right or Left Hand Installation
(Section 5)
See
for converting Flush
Valve to Left Hand Installation.
2
3
4
10'
6
9
10
M965051 REV.1.5