HIGH-STATIC MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET
NOMINAL
UNIT
VOLTAGE
(V-Ph-Hz)
208/230-3-60
48HJE,HJF004
460-3-60
575-3-60
208/230-3-60
48HJD/HJE/HJF005
460-3-60
575-3-60
208/230-3-60
48HJD/HJE/HJF006
460-3-60
575-3-60
208/230-3-60
48HJE/HJF/HJD007
460-3-60
575-3-60
208/230-3-60
48HJD/HJE/HJF008**
460-3-60
575-3-60
208/230-3-60
48HJD/HJE/HJF009**
460-3-60
575-3-60
208/230-3-60
48HJD/HJF/HJE012**
460-3-60
575-3-60
LEGEND
FLA
— Full Load Amps
HACR — Heating, Air Conditioning and Refrigeration
IFM
— Indoor (Evaporator) Fan Motor
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
NEC
— National Electrical Code
OFM
— Outdoor (Condenser) Fan Motor
RLA
— Rated Load Amps
UL
— Underwriters' Laboratories
*Used to determine minimum disconnect per NEC.
†Fuse or HACR circuit breaker per NEC.
**Units have 2 condenser-fan motors.
VOLTAGE
COMPRESSOR
RANGE
(each)
Min
Max
RLA
LRA
187
254
10.3
77.0
414
508
5.1
39.0
518
632
4.2
31.0
187
254
13.5
99.0
414
508
7.4
49.5
518
632
5.8
40.0
187
254
17.3
123.0
414
508
9.0
62.0
518
632
7.1
50.0
187
254
20.5
156.0
414
508
9.6
70.0
518
632
7.7
56.0
187
254
12.4
88.0
414
508
6.4
44.0
632
518
4.8
34.0
187
254
15.0
99.0
414
508
8.2
49.5
518
632
5.8
40.0
187
254
17.3
125.0
414
508
9.0
62.0
518
632
7.1
50.0
COMBUSTION
OFM
IFM
FAN MOTOR
FLA
FLA
RLA
0.7
5.8
0.6
0.4
2.6
0.3
0.4
2.6
0.3
0.7
5.8
0.6
0.4
2.6
0.3
0.4
2.6
0.3
1.5
7.5
0.6
0.8
3.4
0.3
0.8
3.4
0.3
1.4
7.5
0.6
0.6
3.4
0.3
0.6
3.4
0.3
1.4
10.6
0.6
0.7
4.8
0.3
0.7
4.8
0.3
1.4
10.6
0.6
0.7
4.8
0.3
0.7
4.8
0.3
1.4
15.0
0.6
0.7
7.4
0.3
0.7
7.4
0.3
NOTES:
1. In compliance with NEC requirements for multimotor and combina-
tion load equipment (refer to NEC Articles 430 and 440), the over-
current protective device for the unit shall be fuse or HACR
breaker. The UL, Canada units may be fuse or circuit breaker.
2. Electrical data based on 95 F ambient outdoor-air temperature
± 10% voltage.
MINIMUM UNIT
POWER
DISCONNECT
SUPPLY
SIZE*
MCA
MOCP
FLA
LRA
19.4
25†
19
120
9.4
15†
9
7.7
15†
8
23.4
30†
23
142
12.3
15†
12
9.7
15†
9
30.6
35†
30
187
15.5
20†
15
12.2
15†
12
30.6
35†
30
187
15.5
20†
15
12.2
15†
12
41.3
45†
44
267
20.6
25†
22
134
15.8
20†
17
47.2
60†
50
264
24.7
30†
26
132
18.0
20†
19
107
56.7
70
61
360
29.1
35†
29
181
23.0
25†
23
136
60
48
71
57
94
76
94
76
95
53