Performance data (cont)
48HJ009 (8
1
/
TONS) — HIGH-STATIC MOTOR (BELT DRIVE)
2
Airflow
0.2
(Cfm)
Rpm
2550
559
2600
567
2700
582
2800
598
2900
614
3000
630
3100
646
3200
682
3300
679
3400
695
3500
712
3600
729
3700
745
3750
754
3800
762
3900
779
4000
796
4100
813
4200
830
4250
839
4300
847
48HJ009 (8
1
/
TONS) — HIGH-STATIC MOTOR (BELT DRIVE) (cont)
2
Airflow
1.2
(Cfm)
Rpm
2550
864
2600
869
2700
880
2800
892
2900
903
3000
915
3100
926
3200
938
3300
950
3400
963
3500
976
3600
988
3700
992
3750
999
3800
1006
3900
1017
4000
1034
4100
1057
4200
1074
4250
1109
4300
1121
LEGEND
Bhp
Brake Horsepower Input to Fan
FIOP
Factory-Installed Option
NOTES:
1. Boldface indicates field-supplied drive required. (See Note 3.)
2.
indicates field-supplied motor and drive required.
3. Motor drive range is 840 to 1085 rpm for standard motors; 860 to 1080 rpm
for high-static motors. All other rpms require a field-supplied drive.
4. Values include losses for filters, unit casing, and wet coils. See page 49 for
accessory/FIOP static pressure information.
38
FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)
0.4
Bhp
Rpm
Bhp
0.72
634
0.97
0.75
641
1.00
0.83
655
1.08
0.90
670
1.17
0.98
684
1.25
1.07
690
1.35
1.16
714
1.45
1.26
729
1.55
1.36
744
1.66
1.47
759
1.78
1.59
774
1.90
1.71
790
2.03
1.84
805
2.17
1.91
813
2.24
1.98
821
2.31
2.12
836
2.46
2.27
852
2.61
2.42
868
2.78
2.59
884
2.95
2.68
890
3.04
2.76
900
3.13
1.4
Bhp
Rpm
Bhp
2.01
915
2.34
2.06
918
2.37
2.17
927
2.47
2.29
938
2.58
2.42
949
2.71
2.54
961
2.85
2.67
972
3.00
2.81
983
3.14
2.95
995
3.30
3.10
1007
3.45
3.25
1007
3.56
3.41
1019
3.74
3.59
1023
3.94
3.68
1030
4.04
3.77
1038
4.14
4.07
1049
4.46
4.30
1066
4.71
4.77
1090
5.24
5.05
1108
5.54
5.88
1143
6.45
6.05
1156
6.64
External Static Pressure (in. wg)
0.6
Rpm
Bhp
700
1.21
706
1.25
719
1.34
732
1.43
745
1.53
759
1.63
773
1.74
787
1.86
801
1.98
816
2.10
830
2.23
845
2.37
860
2.52
868
2.59
875
2.66
890
2.82
905
2.98
920
3.15
935
3.33
965
3.88
976
3.99
External Static Pressure (in. wg)
1.6
Rpm
Bhp
968
2.81
973
2.81
976
2.84
983
2.92
993
3.03
1003
3.17
1016
3.32
1026
3.47
1022
3.58
1034
3.74
1034
3.86
1047
4.05
1050
4.27
1058
4.38
1066
4.48
1077
4.84
1095
5.11
1119
5.67
1138
6.00
1174
6.98
1188
7.19
5. Maximum continuous bhp is 2.90 for standard motors, 4.20 for high-static
motors. Extensive motor and electrical testing on these units ensures that
the full range of the motor can be utilized with confidence. Using your fan
motors up to the ratings shown will not result in nuisance tripping or prema-
ture motor failure. Unit warranty will not be affected. See Evaporator-Fan
Motor Data tables on pages 47 and 48 for additional information.
6. Use of a field-supplied motor may affect wire sizing. Contact your Carrier
representative to verify.
7. Interpolation is permissible. Do not extrapolate.
0.8
Rpm
Bhp
Rpm
759
1.48
814
764
1.52
819
776
1.61
831
789
1.71
842
802
1.81
854
815
1.92
866
828
2.04
878
841
2.16
891
854
2.29
904
867
2.42
917
881
2.56
930
895
2.71
943
909
2.87
956
917
2.95
963
924
3.03
970
938
3.19
981
953
3.37
996
974
3.74
1019
990
3.96
1036
1022
4.61
1069
1034
4.74
1081
1.8
Rpm
Bhp
Rpm
991
3.02
1012
996
3.02
1017
999
3.05
1021
1006
3.13
1028
1017
3.25
1038
1027
3.40
1049
1040
3.56
1062
1050
3.72
1073
1046
3.84
1069
1059
4.01
1081
1058
4.15
1081
1071
4.35
1094
1075
4.58
1098
1083
4.70
1106
1091
4.81
1114
1103
5.19
1127
1121
5.48
1145
1146
6.09
1170
1165
6.44
1190
1202
7.50
1228
1216
7.72
1242
1.0
Bhp
1.74
1.79
1.89
2.00
2.11
2.23
2.35
2.48
2.61
2.75
2.90
3.05
3.22
3.30
3.38
3.65
3.85
4.28
4.52
5.27
5.42
2.0
Bhp
3.21
3.21
3.25
3.34
3.46
3.62
3.80
3.97
4.09
4.27
4.42
4.63
4.88
5.00
5.12
5.53
5.84
6.49
6.86
7.98
8.22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents