Indoor Unit Installation (1)

3.

Drain piping

1) Use commercial rigid polyvinyl chloride pipe (general VP 20 pipe, outer diameter 26mm, inner diameter 20mm) for the drain pipe.
2) The drain hose (outer diameter 18mm at connecting end, 220mm long) is supplied with the indoor unit. Prepare the drain
pipe picture below position.
3) The drain pipe should be inclined downward so that water will flow smoothly without any accumulation. (Should not be trap.)
4) Insert the drain hose to this depth so it won't be pulled out of the drain pipe.
5) Insulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation.
6) Remove the air filters and pour some water into the drain pan to check the water flows smoothly.
100
CAUTION
Use polyvinyl chloride adhesive agent for gluing. Failure to do so may cause water leakage.
4.

Installing indoor unit

4-1. Preparation
• Open the front panel, remove the 4 screws and dismount the
front grille while pulling it forward.
• Follow the procedure below when removing the slit portions.
■ For Moldings
• Remove the pillars. (Remove the slit portions on the bottom
frame using nippers.)
■ For Side Piping
• Remove the pillars.
1) Remove the 7 screws.
2) Remove the upper casing (2 tabs).
3) Remove the left and right casings (2 tabs on each side).
4) Remove the slit portions on the bottom frame and casings
using nippers.
5) Return by following the steps in reverse order (3 > 2 > 1).
For Moldings
English
150
220
C
Drain hose
Reducer
Vinyl chloride
drain pipe
(VP-20)
Casing
Remove the pillar.
(Unit: mm)
Insert drain hose
to this depth so
it won't be pulled
out of drain pipe.
50mm
or more
Vinyl chloride
drain pipe
(VP-30)
Front grille
Front panel
Remove 4 screws.
3) Side casings
For Side Piping
Must be no trap.
Do not touch water.
3 tabs
Casing
Remove
front grille
Open the front panel.
2) Upper casing
3) Side
Remove 7 screws.
Remove the pillar.
Casing
Bottom frame
Remove the pillar.
casings
9