Removal and Replacement Procedures
Extender Card (SSA Loop) Removal and Replacement
There are 2 (max) SSA Extender cards located in the I/O cage. Extender cards are located in row 0 on
the front of the cage directly over the HDAs. The minimum configuration contains 1 adapter card. These
cards are oriented horizontally in the cage.
Removing the Extender Card (SSA Loop)
1
Turn OFF the S/390 Integrated Server power and disconnect the power cord. Verify that power is
off. (See "Power Off Procedures" on page 142)
2
Open the front of the frame.
3
Locate the Extender Card to be replaced.
4
Disconnect cables from front of card. Label if necessary.
5
Loosen two captive fasteners on the front of the Extender Card.
6
Pull the Extender Card from the slot.
Replacing the Extender Card (SSA Loop)
1
Carefully slide the card into slot until resistance is felt and plug to the backplane.
2
Tighten fasteners on the front of the card.
3
Reconnect the link cables previously removed from the extender card.
)
4
Plug all power cords into the electrical outlets.
5
Run Diagnostics to Verify Installation.
Chapter 8. Removal and Replacement Procedures