Coding
Code 2
(cont.)
Coding in the delivered condition
DHW
56:0
Set DHW temperature
adjustable from 10 to
60 °C
58:0
Without auxiliary func-
tion for DHW heating
59:0
Cylinder heating:
Starting point -2.5 K
Stopping point +2.5 K
5b:0
DHW cylinder directly
connected to the boiler
60:20
During DHW heating,
the boiler water tem-
perature is max. 20 K
higher than the set
DHW temperature
62:2
Circulation pump with
2 min run-on time after
cylinder heating
63:0
Without auxiliary func-
tion for DHW heating
(only for constant tem-
perature control units)
46
Possible change
56:1
Set DHW temperature
adjustable from 10 to
above 60 °C
Note
Maximum value subject
to boiler coding card.
Observe the max. per-
missible DHW tempera-
ture.
58:10
Input of a second set
to
DHW value, adjustable
58:60
from 10 to 60 °C (observe
coding addresses "56"
and "63")
59:1
Starting point adjustable
to
from 1 to 10 K below the
59:10
set value
5b:1
DHW cylinder connected
downstream of the low
loss header
60:5
The difference between
to
the boiler water tempera-
60:25
ture and the set DHW
temperature is adjustable
from 5 to 25 K
62:0
Circulation pump without
run-on
62:1
Run-on time adjustable
to
from 1 to 15 min
62:15
63:1
Auxiliary function: 1 x
daily
63:2
Every 2 days to every 14
to
days
63:14
63:15
2 x daily