Tripp Lite ECO350UPS Owner's Manual page 7

Hide thumbs Also See for ECO350UPS:
Table of Contents

Advertisement

Available languages

Available languages

Quick Installation
ECO Energy Saving
The ECO Energy Saving feature allows your UPS system to save energy by automatically
turning off designated outlets when your computer or other item connected to the "MASTER"
outlet is turned off or in standby mode. The ECO feature is disabled by default.
To enable ECO Energy Saving:
1 Connect nonessential devices that you would like to be automatically powered OFF and
ON to the "CONTROLLED BY MASTER OUTLET" receptacles. Make sure that any devices
connected to these outlets can be powered off automatically without interrupting your
internet connection, local network or other essential services.
2 Select the device from your equipment configuration, such as a desktop computer, AV
receiver or other vital component and connect its power cord to the designated "MASTER"
outlet on the UPS. This master device will serve as the trigger to automatically power-on
all equipment connected to "CONTROLLED BY MASTER OUTLET" receptacles whenever the
device connected to the "MASTER" outlet is powered-on. When the device connected to the
"MASTER" outlet is turned off or enters a low-power sleep mode, devices connected to the
"CONTROLLED BY MASTER OUTLET" receptacles will automatically be powered off.
3 To enable ECO energy-saving mode, double-click the UPS power button while the UPS is
turned on and running from utility power. The UPS confirms ECO mode is engaged via the
LED or LCD interface:
• On single LED models, the green LED flashes off every 10 seconds
• On 3 LED models, the green LED to the left of the PROTECTED LED will flash off every
10 seconds
• On LCD equipped models, the display will report ECO when the ECO status screen
is activated
4 Once ECO energy-saving mode is enabled, the UPS will automatically turn OFF all devices
connected to the "CONTROLLED BY MASTER OUTLET" receptacles approximately 3 minutes
after the device connected to the "MASTER" outlet is turned off or enters a low-power
sleep mode. (The 3 minute delay ensures the controlled outlets remain powered ON during
a reboot). Devices connected to "CONTROLLED BY MASTER OUTLET" receptacles are
automatically powered ON when the device connected to the "MASTER" outlet is powered
back on.
Note: A minimum load is required on the "MASTER" outlet in order for controlled outlets to power ON,
as stated in the table below.
Model
ECO350UPS
ECO550UPS
ECO650UPSM
ECO750UPS
ECO850LCD
ECO900UPSM
ECO900LCDU2
18-10-462-9338D5.indb 7
(All Models)
Required Load
15W
21W
23W
23W
21W
24W
24W
7
1/2/2019 4:16:48 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents