5. Tighten the screw of the hose clamp using a
suitable screwdriver.
Note
After installing the cables, ensure that the EMC tongues of the DC link adapter are in contact
with the side panel of the component.
High Frequency Drive
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
9.6 Electrical connection
6. Fix the second core of the DC link connecting
cable to the profile rail using a cable clamp.
Connect the cable for the DCP connection as
described under Points 2 to 5.
The installed DC link connecting cable is shown
in the adjacent diagram.
DC link adapter