1Ph8087-1_U2 (Fp = 4 Khz) - Siemens SIMOTICS M-1PH8 Commissioning Instructions

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

4.2.7

1PH8087-1_U2 (fp = 4 kHz)

1PH8087-1_U2, operation on Booksize 45 A SLM
Motor/DRIVE CLiQ data
Rated motor voltage
Rated motor voltage
Rated motor power
Rated motor power factor
Rated motor frequency
Rated motor speed
Motor rated magnetizing current/short-circuit
current
Maximum motor speed
Motor stall torque correction factor
Type of motor cooling
Motor moment of inertia
Motor weight (for thermal motor type)
Speed at the start of field weakening Vdc =
600 V
Motor stator resistance, cold
Cold motor rotor resistance/damper re-
sistance d-axis
Motor stator leakage inductance
Motor rotor leakage inductance/damping
inductance d axis
Motor magnetizing inductance/magnetizing
inductance d axis, saturated
Mot_temp_mod 2/KTY warning threshold
Mot_temp_mod 1/2 threshold
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
400 V
p304
354
p305
25.1
p307
11.0
p308
0.762
p310
169.0
p311
5,000
p320
12.4
p322
24,000
p326
55
p335
2
p341
0.0094
p344
41
p348
p350
0.178
p354
0.138
p356
0.619
p358
1.001
p360
15.248
p604
150
p605
170
Converter data sheets and characteristics
Booksize 45 A ALM
4.2 Water cooling
480 V
354
25.1
11.0
0.762
169.0
5,000
12.4
24,000
55
2
0.0094
41
0.178
0.138
0.619
1.001
15.248
150
170
67