Siemens SIMOTICS M-1PH8 Commissioning Instructions page 56

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

Converter data sheets and characteristics
4.2 Water cooling
Additional parameterization
Motor type selection
Line resistance
Current controller adaptation, starting point
KP
Current controller adaptation, starting point
KP adapted
Current controller adaptation, P gain adapta-
tion
Current limit
Maximum rotation speed
Torque limit, upper/motoring
Torque limit, lower/regenerative
Power limit, motoring
Power limit, regenerative
Maximum field-generating current
Pulse frequency setpoint
Modulator configuration
Current controller P gain
Reference speed reference frequency
Reference current
Reference torque
Hysteresis speed n_act > n_max
56
400 V
p300
p352
0.03477
p391
p392
40
p393
60
p640
77
p1082
24,000
p1520
31.8
p1521
- 31.8
p1530
30
p1531
- 30
p1603
p1800
p1810
"&H800"
p1715
2.9
p2000
24,000
p2002
77
p2003
31.8
p2162
480
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Booksize 45 A
1
0
0
4
Commissioning Manual, 10/2014, 610.40106.40
480 V
1
0.03477
0
40
60
77
24,000
31.8
- 31.8
30
- 30
0
4
"&H800"
2.9
24,000
77
31.8
480

Advertisement

Table of Contents
loading

Table of Contents