1PH8083-1_T2, operation on Booksize 60 A
Motor/DRIVE CLiQ data
Rated motor voltage
Rated motor voltage
Rated motor power
Rated motor power factor
Rated motor frequency
Rated motor speed
Motor rated magnetizing current/short-circuit
current
Maximum motor speed
Motor stall torque correction factor
Type of motor cooling
Motor moment of inertia
Motor weight (for thermal motor type)
Speed at the start of field weakening Vdc =
600 V
Motor stator resistance, cold
Cold motor rotor resistance/damper re-
sistance d-axis
Motor stator leakage inductance
Motor rotor leakage inductance/damping
inductance d axis
Motor magnetizing inductance/magnetizing
inductance d axis, saturated
Mot_temp_mod 2/KTY warning threshold
Mot_temp_mod 1/2 threshold
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
400 V
p304
336
p305
24.0
p307
9.0
p308
0.79
p310
402.9
p311
12,000
p320
11.2
p322
24,000
p326
60
p335
2
p341
0.0069
p344
34
p348
p350
0.089
p354
0.067
p356
0.261
p358
0.442
p360
6.580
p604
150
p605
170
Converter data sheets and characteristics
Booksize 60 A
4.2 Water cooling
480 V
336
24.0
9.0
0.79
402.9
12,000
11.2
24,000
60
2
0.0069
34
0.089
0.067
0.261
0.442
6.580
150
170