Siemens SIMOTICS M-1PH8 Commissioning Instructions page 42

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

Converter data sheets and characteristics
4.1 Forced ventilation
Additional parameterization
Motor type selection
Line resistance
Current controller adaptation, starting point
KP
Current controller adaptation, starting point
KP adapted
Current controller adaptation, P gain adapta-
tion
Current limit
Maximum rotation speed
Torque limit, upper/motoring
Torque limit, lower/regenerative
Power limit, motoring
Power limit, regenerative
Maximum field-generating current
Pulse frequency setpoint
Modulator configuration
Current controller P gain
Reference speed reference frequency
Reference current
Reference torque
Hysteresis speed n_act > n_max
42
400 V
p300
p352
0.12
p391
p392
10
p393
50
p640
67.8
p1082
24,000
p1520
20
p1521
-20
p1530
25.1
p1531
-25.1
p1603
90
p1800
p1810
"&H800"
p1715
3.3
p2000
24,000
p2002
67.8
p2003
20
p2162
480
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Booksize 60 A
1
8
8
Commissioning Manual, 10/2014, 610.40106.40
480 V
1
0.12
8
10
50
67.8
24,000
20
-20
27.2
-27.2
90
8
"&H800"
3.3
24,000
67.8
20
480

Advertisement